OilMax
Matrix acidizing diverter
Direct treatments away from intervals with high water cut, improving stimulation and minimizing produced water volume.
Water and gas conformance service
Water production characteristics and causes vary significantly from well to well, and water strategies vary among operators and locations. To accommodate this variety, the AllSeal water and gas conformance service integrates a wide portfolio of shutoff technologies from relative permeability modifiers (RPMs) and temporary chemical blocks to permanent cements.
We select the right solution based on your field and operational requirements, reservoir characteristics, economic constraints, logistics, and best practices gathered over decades of work around the world. The result is a fit-for-purpose solution matched to your particular well or situation.
Gas breakthrough is common in naturally fractured oil reservoirs or through leaks in cement or casing. Increasing gas production reduces crude oil production. Eventually the well becomes uneconomic, leading to shutting in the well despite its potentially recoverable reserves.
AllSeal service provides engineered alternatives to continue or restore production to these wells and recover otherwise lost reserves, which can significantly improve the economics of operating the field.
Conformance Technology | System Description | Water Control Application | Gas Control Application | Wellbore and Perforations Treatment Penetration | Matrix Treatment Penetration | Fracture Networks Treatment Penetration | Acid Resistant Chemical Resistance | H2S Resistant Chemical Resistance | C02 Resistant Chemical Resistance | Injector | Max. Application Temperature, degF [degC] | Viscosity Range, cP |
MARA-SEAL† system | Rigid crosslinked polyacrylamide gel | √ | √ | √ | √ | <100 ppm | √ | √ | 250 [121] | 100 | ||
OrganoSEAL R rigid organic crosslinked gel system | Rigid organic crosslinked polyacrylamide gel | √ | √ | √ | √; | Yes, after gelation | √ | √ | 325 [163] | 100 | ||
H2S-tolerant gel system | Rigid organic crosslinked specialty polymer gel | √ | √ | √ | √ | √ | √ | √ | 250 [121] | 20–80 | ||
FoamSEAL stable crosslinked foaming gel | Crosslinked foamed polyacrylamide gel | √ | √ | √ | √ | √ | <100 ppm | √ | √ | 325 [163] | 100 | |
MARCIT† system | Flowing crosslinked polyacrylamide gel | √ | √ | √ | √ | <100 ppm |
√ | √ | 200 [93] | 50–300 | ||
OrganoSEAL F flowing organic crosslinked gel system | Flowing organic crosslinked polyacrylamide gel | √ | √ | √ | √ | Yes, after gelation | √ | √ | 325 [163] | 50–300 | ||
ZONELOCK permanent zone sealing fluid system | Rigid inorganic gel | √ | √ | √ | √ | √ | 180 [82] | 1–2 | ||||
Delayed gelation system (DGS) | Rigid delayed gelation inorganic gel | √ | √ | √ | √ | 200 [93] | 1–2 | |||||
Particulate gel system | Physical plugging gel | √ | √ | √ | √ | √ | √ | 350 [177] | 10 | |||
ZONETROL XT zonal water conformance system | Relative permeability modifier | √ | √ | 250 [121] | 10 | |||||||
FracCON water-conformance fracturing fluid | Water-conformance fracturing fluid | √ | Matrix near fracture faces | 250 [121] | 100–300 | |||||||
OilMAX matrix acidizing diverter | Matrix acidizing diverter for high-water-cut wells | √ | √ | 250 [121] | 10 | |||||||
Annular cement packer (ACP) | Annular cement packer | √ | √ | √ | √ | √ | √ | √ | 195 [91] | |||
WaterSEEKER Gel water-reactive polymer system | Water-reactive polymer | √ | √ | √ | √ | Yes, after gelation | √ | 325 [163] | ||||
WATERSEEKER Cement water-reactive cement system | Water-reactive cement | √ | √ | √ | √ | √ | 325 [163] | |||||
SqueezeCRETE remedial cementing solution | Microcement system | √ | √ | √ | √ | √ | √ | √ | 320 [160] | 60 |
†Service marks of Marathon Oil Corporation