Integrity HPHT Subsurface Safety Valve | SLB

Integrity HPHT subsurface safety valve

Engineered, tested, and qualified to function effectively even at extremely high pressures and temperatures

minus

Designed for longevity and resilience in HPHT wells

When actuated from surface—either manually or through an automated control system—Integrity™ HPHT subsurface safety valves slam shut to secure the well. Part of the family of Integrity subsurface safety valves, these valves have been rigorously tested and qualified far beyond the requirements of API Spec 14A.

Rated to 15,000 psi [103,420 kPa]
Working temperature up to 350 degF [177 degC]
Validated to API Spec 14A V1-R
Tubing size: 5.5 in
Cutaway view of Integrity HPHT subsurface safety valve showing its internals.

These valves are set at shallow depths in HPHT oil and gas wells.

Preserve the integrity of your well

Integrity HPHT safety valves serve as the ultimate defense in the complex process of HPHT oil and gas production, safeguarding operations and personnel in the event of compromised well integrity.

The valves have a robust design, with patented seal technology and resilient materials that are specifically chosen for their durability—a critical factor given the potential impact of HPHT conditions on long-term valve integrity. Rigorous testing and qualification processes ensure valve performance at extreme temperatures and pressures, especially during emergency closures.

The valve actuator incorporates multizone seal technology to provide a dynamic seal solution that surpasses traditional seal systems in reliability. Designed for high performance and longevity, the actuator requires hydraulic pressure for operation, which simplifies control system requirements. This combination of advanced technology and thoughtful design ensures the effectiveness and dependability of Integrity HPHT safety valves.

How are the valves qualified?

The valves are validated to API Spec 14A V1-R, but their performance exceeds the certification requirements.

Flapper leakage: API Spec 14A allows leakage up to 5 ft3/min. The acceptance criterion for Integrity HPHT safety valve flapper systems is bubble-tight performance.

Hydraulic actuator integrity: API Spec 14A allows up to 5% drop in applied hydraulic pressure; for 10,000-psi hydraulic pressure, the acceptable leakage is 500 psi. Integrity HPHT safety valve actuators allow <1% drop, as confirmed by rigorous tests.

Slam closure: The valve's flapper system has been successfully slam tested at high flow rates that exceed the Annex K requirements of API Spec 14A.