Product Sheet CN NATCO SHV Flare
Burn unwanted emissions and comply with environmental regulations governing VOC emissions.
Emission control system
The NATCO SHV Flare emission control system can be installed downstream of glycol reboiler still columns to burn unwanted emissions and help gas producers comply with environmental regulations governing benzene, toluene, ethylbenzene, and xylene (BTEX) and volatile organic compound (VOC) emissions.
The proprietary system delivers BTEX and VOC destruction efficiency of 95%–98%. Reboiler emission vapors are superheated before being burned to eliminate costly liquid disposal.
The system and piping are designed to reduce backpressure on the atmospheric glycol reconcentration system. This design feature prevents glycol contamination in the reboiler surge tank. The vapor superheater uses waste heat from the reboiler flue gas to superheat the emissions, so no other heat source is required. The system also provides emission control for new or existing glycol dehydration systems, with easy retrofitting of existing units.
Model | Waste Gas, lbm/hb Min. | Waste Gas, lbm/hb Max. | Assist Gas, lbm/h 5 psi | Assist Gas, lbm/h 20 psi | Mix Eductor | Standpipe, ft |
---|---|---|---|---|---|---|
Model 2S | Waste Gas, lbm/hb Min. 0 | Waste Gas, lbm/hb Max. 25 | Assist Gas, lbm/h 5 psi 1.9 | Assist Gas, lbm/h 20 psi 3.4 | Mix Eductor 2 | Standpipe, ft 8 |
Model 2l | Waste Gas, lbm/hb Min. 25 | Waste Gas, lbm/hb Max. 60 | Assist Gas, lbm/h 5 psi 7.8 | Assist Gas, lbm/h 20 psi 13.7 | Mix Eductor 2 | Standpipe, ft 8 |
Model 2.5S | Waste Gas, lbm/hb Min. 60 | Waste Gas, lbm/hb Max. 100 | Assist Gas, lbm/h 5 psi 9.16 | Assist Gas, lbm/h 20 psi 16.1 | Mix Eductor 2.5 | Standpipe, ft 8 |
Model 2.5L | Waste Gas, lbm/hb Min. 100 | Waste Gas, lbm/hb Max. 175 | Assist Gas, lbm/h 5 psi 21.7 | Assist Gas, lbm/h 20 psi 38.2 | Mix Eductor 2.5 | Standpipe, ft 8 |
Model 3 | Waste Gas, lbm/hb Min. 175 | Waste Gas, lbm/hb Max. 300 | Assist Gas, lbm/h 5 psi 30.4 | Assist Gas, lbm/h 20 psi 53.6 | Mix Eductor 3 | Standpipe, ft 12 |
Model 4 | Waste Gas, lbm/hb Min. 300 | Waste Gas, lbm/hb Max. 450 | Assist Gas, lbm/h 5 psi 52.0 | Assist Gas, lbm/h 20 psi 91.7 | Mix Eductor 4 | Standpipe, ft 12 |
Model 5 | Waste Gas, lbm/hb Min. 450 | Waste Gas, lbm/hb Max. 650 | Assist Gas, lbm/h 5 psi 74.6 | Assist Gas, lbm/h 20 psi 132 | Mix Eductor 5 | Standpipe, ft 16 |
Model 6 | Waste Gas, lbm/hb Min. 650 | Waste Gas, lbm/hb Max. 950 | Assist Gas, lbm/h 5 psi 132 | Assist Gas, lbm/h 20 psi 233 | Mix Eductor 6 | Standpipe, ft 18 |