OptiDrill Service Eliminates 18-in Liner, Saves Statoil 10 Rig Days in Deepwater Exploration Well, Angola | SLB

OptiDrill Service Eliminates 18-in Liner, Saves Statoil 10 Rig Days in Deepwater Exploration Well, Angola

已发表: 09/10/2015

Blue hero texture

Eliminate intermediate 18-in liner in deepwater well with shock and vibration expected

After drilling its first vertical exploration well in the presalt area of the Jacare field offshore Angola, Statoil aimed to eliminate the planned intermediate 18-in liner in the subsequent well. To accomplish this objective, Statoil would need to drill the 18 1/8-in section to the planned TD for the next section. This would require drilling through the salt in minimum time while opening the borehole to 21 in, and, ideally, in one run to avoid salt creep. If extended, this 18 1/8-in hole would be drilled from 2,555 m [8,382 ft] to 5,647 m [18,527 ft], passing through a layer of hard stringers at approximately 4,350 m [14,272 ft]—the original TD for the 181/8-in section.

Based on the first well drilled, Statoil anticipated shock and vibration in medium to hard salt formations that would negatively affect BHA performance. In the first well, this resulted in the need for a second bit run. Interbedded formations would likely make managing weight on reamer challenging and lead to premature cutting structure damage.

Use OptiDrill service to enhance BHA performance

Based on the length of the run and prejob modeling, Schlumberger recommended a multisegment solution with a primary focus on the use of the OptiDrill real-time drilling intelligence service. The OptiDrill service provides downhole drilling mechanics and dynamics measurement on a rigsite display for improved decision making. This information is also made available offsite for remote interpretation by the drilling team.

With increased knowledge of downhole conditions, Statoil could optimize drilling parameters to improve ROP, mitigate risk, and enhance cutting structure life. To improve management of vibration and to optimize bit and reamer weight distribution, Schlumberger recommended remote interpretation by a drilling analyst from Geoservices, a Schlumberger company. The BHA included the PowerDrive X6 RSS and Rhino system to maintain verticality and open the 18 1/8-in hole to 21 in.

Drilled 3,100 m of salt interval in one run, saving Statoil 10 days

Using the OptiDrill service and complementary technologies and services, Statoil accurately applied optimal drilling parameters. This led to enhanced BHA performance that enabled Statoil to drill through the Angolan salt at a record-breaking 30-m/h ROP and set a record for the longest salt run ever drilled in Angola. Furthermore, verticality was maintained throughout the interval, and the hole was underreamed without premature wear to cutting structures.

“We successfully drilled 3,100 m of a salt section in one run and avoided setting a potential intermediate liner in the salt, thereby saving around 10 days,” Statoil Drilling Engineer Marcel Emile Ngueguim said. “We recommend the use of the OptiDrill service where accurate information is needed to improve drilling performance and bit life, especially in deep water with hard or abrasive formations. It is also recommended in underreaming applications to accurately evaluate the weight distribution between the reamer and the bit.”

Graph: OptiDrill Service Eliminates 18-in Liner, Saves Statoil 10 Rig Days in Deepwater Exploration Well, Angola - The OptiDrill service provided Statoil with a clear real-time visualization of downhole events, such as weight distribution between the bit and the underreamer alongside formation evaluation data.
The OptiDrill service provided Statoil with a clear real-time visualization of downhole events, such as weight distribution between the bit and the underreamer alongside formation evaluation data.

“We successfully drilled 3,100 m of a salt section in one run and avoided setting a potential intermediate liner in the salt, thereby saving around 10 days.” Marcel Emile, Ngueguim Drilling Engineer, Statoil

地点
Angola, Africa, 海上
Feature.PageContent.LeftRailDetails.Title

Challenge: Maximize drilling performance and save rig days by eliminating intermediate 18-in liner in a vertical exploration presalt well.

Solution:

  • Mitigate risk and maximize performance with the OptiDrill real-time drilling intelligence service
  • Maintain verticality with the PowerDrive X6 rotary steerable system (RSS) and enlarge the borehole with the Rhino integrated borehole enlargement system
  • Use expert drilling analysis from Geoservices, a Schlumberger company, to optimize drilling parameters

Results:

  • Eliminated 18-in liner, saving 10 rig days
  • Drilled 3,100-m [10,170-ft] interval, setting a record for the longest salt run ever drilled in Angola
  • Achieved 30-m/h [98-ft/h] ROP, breaking the record for the highest average ROP in Angolan salt
  • Enlarged 18 1/8-in hole to 21 in while maintaining optimal weight distribution
相关产品