已发表: 04/15/2011
已发表: 04/15/2011
Well Information |
|
Well Name | Domial - 2 |
Location | Punjab, Pakistan |
Spud Date | October 22, 2010 |
Intervals | 26 in, 17 ½ in. and 12 ¼ in. |
Casing Size | 20 in x 13 ⅜ in |
Inclination | 1.5° |
As with most wells, M-I SWACO uses corrosion coupons during this particular project to monitor the corrosion rate while drilling to ensure it remains under an acceptable limit (<2 lb/ft2/yr). An analysis of the first coupon installed in the HWDP – DP tool joint yielded a very high corrosion rate (>30 lb/ft2/yr), which was totally unacceptable.
The operator accepted the M-I SWACO recommendation to use Conqor 404 corrosion inhibitor, and to maintain the system pH at or above 10.5.
The results obtained were quite extraordinary. The corrosion rate dropped below the minimal acceptable range, which ultimately allowed the client to:
A Pakistan oilfield operator and one of the largest national oil and gas exploration company of Pakistan faced corrosion issues in their drilling campaign. The operator was drilling the appraisal well, Domial-2 with TD 15,500 ft MD (4,724 m). This Potwar region is considered to be very challenging for drilling; handling losses and high pressure water kicks are quite common in this region. While drilling 17 ½ in. section M-I SWACO ran a corrosion coupon. After exposing the ring for 216 hours the analysis showed a severe corrosion rate (30.15 lb/ft2/yr). The operator was briefed on the situation and agreed to immediately treat the mud system with Conqor 404 corrosion inhibitor. The inhibitor was added and the pH raised and was maintained around 10.5. After the treatment the results showed dramatic decrease in corrosion rate to <2 lb/ft2/yr.
“While drilling a deep well for one of our national clients, a Pakistani Oilfield Operator, a severe corrosion problem was observed (corrosion rate = 30.15 lb/ft2/yr). The client accepted our recommendation to raise the pH and treat the system with 0.9 lb / bbl Conqor* 404 corrosion inhibitor to maintain pH around 10.5. After the treatment, we observed a dramatic decrease in the corrosion rate which came under acceptable limit f Zia Haider Shah, M-I SWACO area engineer
If you’d like to know more about the Conqor 404 corrosion inhibitor and how its performed for our other customers, please call the M-I SWACO office nearest you.
Challenge: As with most wells, M-I SWACO uses corrosion coupons during this particular project to monitor the corrosion rate while drilling to ensure it remains under an acceptable limit (<2 lb/ft2/yr). An analysis of the first coupon installed in the HWDP – DP tool joint yielded a very high corrosion rate (>30 lb/ft2/yr), which was totally unacceptable
Solution: The operator accepted the M-I SWACO recommendation to use CONQOR 404 corrosion inhibitor, and to maintain the system pH at or above 10.5
Results: The results obtained were quite extraordinary. The corrosion rate dropped below the minimal acceptable range, which ultimately allowed the client to: