Quick-Acting FORM-A-BLOK Pill Slurry Remedies Severe Lost Circulation in Horizontal Wells | SLB

Quick-Acting FORM-A-BLOK Pill Slurry Remedies Severe Lost Circulation in Horizontal Wells

已发表: 07/06/2016

Blue hero texture

Drilling horizontal intervals in dolerite hindered by severe lost circulation

An operator developing two horizontal wells in an eastern Siberia oil field experienced lost circulation while drilling dolerite. In the first well, no returns occurred at a depth of 3,727 ft [1,136 m], and attempts to clear the circulation using a conventional lost circulation pill were ineffective. Due to the inefficiency of the pill, process water was used in further drilling operations.

In the second well, lost circulation of 2,906 galUS/h [11 m3/h] was observed at a depth of 4,167 ft [1,270 m], and returns stopped at a depth of 4,177 ft [1,273 m]. Due to lost circulation material (LCM) concentration and BHA limitations on the bridging agent, drilling continued using process water and without returns.

Deploying FORM-A-BLOK pill to eliminate complications

M-I SWACO suggested using a FORM-A-BLOK pill, a quick-acting, cost-effective solution with high filtering capacity to eliminate lost circulation. The pill spotting procedure was similar for both wells. While drilling the trap-intrusion interval, a 2,114-galUS [8-m3] lost circulation pill with a filler concentration of 1 lbm/galUS [120 kg/m3] and a total bridging agent content of 11.4% was injected into the well.

Another 2,114-galUS FORM-A-BLOK pill and 0.83 lbm/galUS [100 kg/m3] of chalk were injected and squeezed with process water. After retrieving the BHA above the lost circulation pills, squeezing began with a closed BOP into the lost circulation formation until pressure rose from 441 psi [3.04 MPa] to 588 psi [4.05 MPa].

Improving circulation in horizontal drilling operation

Deploying the FORM-A-BLOK pill eliminated lost circulation in the first well. In the second well, circulation improved from no returns to 17,435 galUS/h [66 m3/h]. As a result, placing cement plugs on both wells was successful on the first try. In previous wells, placing the proper isolation barrier using standard bridging agents failed, requiring up to four plugging operations to isolate the lost circulation zone.

Quick-Acting FORM-A-BLOK Pill Slurry Remedies Severe Lost Circulation in Horizontal Wells
Pressure and flow rate results after squeezing a FORM-A-BLOK pill into the second well. Pressure packs were made with a 475,510-galUS/h [1,800-m3/h] capacity and limited by the maximum pressure of 441 psi [3 MPa].
地点
Russia, Europe, 陆上
Feature.PageContent.LeftRailDetails.Title

Challenge: Overcome severe lost circulation event while drilling dolerite intervals of two horizontal wells onshore Russia

Solution: Use FORM-A-BLOK high-performance, high-strength lost circulation pill

Results: Eliminated lost circulation in one well and substantially reduced lost circulation severity in second well

相关产品