Filtration control at ultrahigh temperatures.
已发表: 05/15/2013
已发表: 05/15/2013
Well Information |
|
Location | Norwegian North Sea |
Sections | 12 ¼ in and 8 ½ in reservoir |
Depth | 12 ¼ in: 2859 – 3470 m (9380-11,385 ft) MD |
8 ½ in: 3470- 3715 m (11,385 – 12,188 ft) MD | |
Bottomhole temperature . | 125° C (257° F) |
Water depth | 4413 ft (1345m) |
The operator requested a fluid suitable to deliver maximum performance for its deepwater exploratory well. The challenging well carried potential risks associated with gas influx, narrow operational window, downhole losses, and hole stability issues.
Based on the experience of M-I SWACO in the North-Sea, a paraffin-based PARATHERM HTHP low-viscosity system was selected to drill the well. The characteristics of the PARATHERM HTHP system, including a low-viscosity profile, excellent hole cleaning capability, low equivalent circulating density (ECD) values, and high resistance to contaminants made it an ideal selection for this challenging exploration well. For this system, the standard VERSATROL HT additive was substituted with the ONE-TROL HT fluid-loss control agent to achieve superior HTHP filtration control with minimum viscosity impact. This is especially important at the lower temperatures of deepwater environment. ONE-TROL HT also improves overall emulsification and thermal stability of the drilling fluid.
The ONE-TROL HT fluid loss additive proved to be a successful solution under all drilling conditions. The HTHP fluid loss control, on both paper and ceramic discs, were controlled easily under given company specifications.
The well was successfully drilled, and all client objectives achieved. The rates of penetration (ROP) were as expected and the well was drilled with no fluids-related non-productive time (NPT). The hole condition remained excellent throughout the drilling operation.
Typical concentrations range from 18 – 30 kg/m³ with occasional daily additions in the range from 1.0 – 3.5 kg/m3.
If you’d like to know more about the ONE-TROL HT additive and how it’s performing for our other clients, please call an M-I SWACO office near you.
Challenge: The well carried potential risks associated with gas influx, narrow operational window, downhole losses, and hole stability issues.
Solution: Based on the experience of M-I SWACO in the North-Sea, a paraffin-based PARATHERM HTHP low-viscosity system was selected to drill the well.
Results: