Kuwait Oil Company Restores Oil Production to 800 bbl/d Using Digital-Slickline-Conveyed Straddle System | SLB

Kuwait Oil Company Restores Oil Production to 800 bbl/d Using Digital-Slickline-Conveyed Straddle System

已发表: 11/19/2019

Blue hero texture

ESP production challenges

Wells with ESP completions can be prone to tubing integrity issues. Fluid recirculation within the tubing can stop well production, and often a rig workover is then required to replace damaged tubing or leaks. This can result in well shutdown for at least 60 days, deferring production and increasing costs.

What Schlumberger recommended

A digital-slickline-conveyed straddle system—including Peak Well Systems’ leak detection tool and SIM system retrievable bridge plugs and straddle tubes—was used to accurately detect the depth of the leak and provide reliable zonal isolation.

How the straddle system restored production

The leak detection tool was deployed downhole using digital slickline to deliver downhole measurements to the surface in real time. The digital inline flowmeter accurately identified the leak within a 9-ft interval.

SIM sealing integrity management system deployed downhole, 3D rendered image
The deployed straddle system included stackable SIM system straddle tubes—available in 5-, 10- and 15-ft lengths—set between an upper and lower bridge plug to isolate across the straddled zone.

The Schlumberger team then ran 40 ft of stackable SIM system straddle tubes downhole between a lower and upper SIM system retrievable bridge plug to isolate the leakage and enable the well to resume production through the straddle, bypassing the leakage point.

 

Digital slickline accurately deployed the straddle system in five runs. After successful deployment, the ESP was started and wellhead pressure increased, immediately indicating that the leakage point had been isolated.

 

A GOR test showed the well producing oil at 800 bbl/d. Because of this unique intervention, KOC saved millions of dollars in deferred production as well as the costs associated with deploying a workover rig. 

Log showing inline flow, temperature, and pressure at depth
The digital inline flowmeter accurately detected flow to identify the leak.
Log showing inline flow, temperature, and pressure at depth
Graph comparing SIM straddle system with CCL showing from Upper SIM system retrievable bridge plug at 3,503 ft to Lower SIM system retrievable bridge plug at 3,550 ft
The straddle system using SIM system technologies accurately confirmed setting depth vs. a CCL.
Graph comparing SIM straddle system with CCL showing from Upper SIM system retrievable bridge plug at 3,503 ft to Lower SIM system retrievable bridge plug at 3,550 ft
地点
Kuwait, 亚洲
Feature.PageContent.LeftRailDetails.Title

Kuwait Oil Company (KOC) needed to determine the depth of and isolate a tubing leak to restore oil production in a well with an ESP completion. Peak Well Systems, a Schlumberger company, conveyed on digital slickline its leak detection tool and SIM sealing integrity management system to accurately detect and isolate the leak, avoiding a workover and returning production to 800 bbl/d with minimal economic impact.