Laboratory Testing Proves Elastomeric Seal Integrity at 45% H2S Concentration | SLB

Laboratory Testing Proves Elastomeric Seal Integrity at 45% H2S Concentration

已发表: 02/21/2018

Schlumberger Oilfield Services
Top image: Test cells for exposing elastomer samples to simulated well conditions. Bottom left image: Test pit (covered) for full-scale testing of BOPs in the presence of H2S. Bottom right image: Schlumberger technicians monitoring elastomer performance.
Top image: Test cells for exposing elastomer samples to simulated well conditions. Bottom left image: Test pit (covered) for full-scale testing of BOPs in the presence of H2S. Bottom right image: Schlumberger technicians monitoring elastomer performance.
地点
美国, North America, 陆上
Feature.PageContent.LeftRailDetails.Title

Cameron H2S Testing Facility

Brookshire, Texas, USA

Pressure
1,000 psi [69 MPa]
 
Temperature
190 degF [87 degC]
 
Duration
24 and 48 h

背景

Reliability of elastomeric seals directly correlates with protection against blowouts, particularly in severe service conditions. Cameron drilling compounds were put to H2S tests that consisted of gas mix (45% H2S, 10% CO2, and balance CH4), diesel, and water. To simulate service conditions, these controlled tests were conducted under conditions of 1,000 psi for 24 and 48 h at 190 degF. This new elastomer demonstrates a 29% increase in H2S concentration accommodation compared with existing compounds used in BOPs, which have passed testing at 35%.